Aimbio Molecular POCT Solution
Sample-in-Result-out - Lab-grade PCR Results in 1.5 Hours, Anywhere
Hangzhou Zhunxin Biotechnology Co., Ltd. | www.aim-bio.net | 2026-09
This document covers the solution only - which products and technical capabilities Aimbio uses to move molecular testing to the point of need. Application scenarios are covered in the companion document, Molecular POCT Application Scenarios. Confirmed wording: Hangzhou Zhunxin Biotechnology Co., Ltd., 1.5 hours to result, 60+ team members.
1. Solution Overview
The solution in one sentence: Aimbio turns molecular diagnostics into a one-minute procedure with an automated instrument plus a single-use closed freeze-dried cartridge - add the sample, close the cartridge, and 1.5 hours later read lab-grade PCR results with Ct values. No PCR laboratory, no manual extraction.
1.1 Three Testing Pathways Compared
|
Dimension |
Central laboratory PCR |
Rapid antigen / antibody test |
Aimbio molecular POCT |
|
Principle |
Real-time fluorescent PCR |
Immunochromatography |
Real-time fluorescent PCR (gold-standard method) |
|
Time to result |
Days (including transport and queuing) |
15–20 minutes |
1.5 hours (including automated extraction and amplification) |
|
Sensitivity |
High |
Lower; often misses early or low-load infections |
High (200–500 copies/mL for most panels; 100 copies/mL for HBV/HCV/HIV) |
|
Multiplexing |
Supported |
Usually single target |
Up to 8 targets per run across 5 fluorescence channels |
|
Operator requirement |
Professional PCR laboratory, certified staff, partitioned rooms |
Very low |
Low - fully automated, no manual reagent preparation |
|
Site requirement |
Fixed laboratory |
Anywhere |
Anywhere: clinic bench, vehicle, farm, border post |
1.2 Compliance & Certification
|
Subject |
Regulation |
Classification / Route |
Date signed |
EU Representative |
|
AIMDX 1800 nucleic acid amplification analyzer + Aim Cartridge |
IVDR (EU) 2017/746 |
Class A (Annex VIII Rule 5); self-declaration under Article 17 with technical documentation drawn up in accordance with Annexes II and III; Basic UDI-DI 697603788AIMDX1800R4, EMDN W02050116 |
[no printed date on the scanned document] |
Lotus NL B.V., The Hague, Netherlands; SRN NL-AR-000000121 (manufacturer SRN CN-MF-000028333) |
|
11 nucleic acid detection kits (respiratory pathogen panel, lower respiratory tract infection panel, Plasmodium panel, MTB, HPV genotyping, HLA-B27, Candida auris, arbovirus panel, MRSA, Norovirus GI/GII, GBS) |
IVDD 98/79/EC |
ANNEX II "Others"; conformity assessment route Annex III (excluding 6) |
2025-05-20 (original declaration 2022-05-21; this amendment only changes the EU representative) |
CMC Medical Devices & Drugs S.L, Malaga, Spain |
Applicable standards: EN ISO 13485:2016, ISO 14971:2019, EN ISO 18113-1:2011, EN ISO 18113-3:2011, ISO 15223-1:2021, EN ISO 23640:2015, EN 13612:2002, EN 13641:2002, EN 13975:2003, IEC 61010-1:2010/A1:2016/C1:2019, IEC 61010-2-010:2019, IEC 61010-2-081:2019, IEC 61010-2-101:2018, IEC 61326-1:2020 RLV, EN 61326-2-6:2020, EN 62366-1:2015.
2. Product Portfolio
|
Component |
Key specifications |
Role in the solution |
|
AIMDX 1800 |
2 qPCR chambers, 5 fluorescence channels, up to 8 targets per run, multiplex RT-qPCR/qPCR; about 1 minute of hands-on loading, results in 1.5 hours |
Single-instrument rapid testing: clinics, border posts, vehicles, pond side |
|
AIMDX 8800 |
Dual modules, up to 8 samples in parallel |
Batch workloads: regional laboratories, large farms, screening programmes |
|
AIM Cartridge |
Single-use, fully closed cartridge with preloaded freeze-dried extraction and PCR reagents, magnetic-bead extraction, sample-in-result-out |
Removes manual reagent handling and contamination risk, so molecular testing can run outside a laboratory |
|
Sample types |
Nasopharyngeal, oropharyngeal and conjunctival swabs, anticoagulated blood, plasma/serum, pleural effusion, ascites, BALF and other body fluids, cells and tissue homogenate, faeces |
Covers human and veterinary sample types (some, such as faeces, require pre-treatment) |
3. Workflow: Sample-in-Result-out
Sampling: collect the appropriate sample type as described in the IFU; certain samples such as faeces require pre-treatment.
Loading: add the sample to the AIM Cartridge - all hands-on steps take about one minute.
Fully automated run: once the cartridge is inserted, the instrument performs magnetic-bead nucleic acid extraction and purification, reconstitution of the freeze-dried reagents, multiplex RT-qPCR/qPCR amplification and fluorescence acquisition, all inside a closed system.
Result: interpreted results and Ct values are generated automatically in 1.5 hours.
Reporting and integration: results can be printed and exported, and LIS/HL7 integration is supported [protocol version and details are defined in the interface documentation].
4. Core Technology & Performance
|
Capability |
How it is delivered |
What it means for the customer |
|
Fully automated nucleic acid extraction |
Magnetic-bead extraction and purification built into the cartridge, with freeze-dried reagents preloaded |
No manual reagent preparation, no extraction instrument, no partitioned laboratory |
|
Fully closed single-use cartridge |
Extraction and amplification happen in the same closed consumable |
Lower cross-contamination and biosafety risk; the used cartridge is discarded as a whole |
|
Multiplex detection |
2 qPCR chambers plus 5 fluorescence channels, up to 8 targets per run |
Differentiate multiple pathogens from one sample, saving sample volume and waiting time |
|
Gold-standard methodology |
Real-time PCR / RT-qPCR with Ct values reported |
Comparable, traceable results suitable for clinical interpretation |
|
Sensitivity |
200–500 copies/mL for most panels; 100 copies/mL for HBV, HCV and HIV |
Early and low-load infections are less likely to be missed |
|
Reagent stability |
Freeze-dried reagents preloaded in the cartridge, shipped under cold chain |
Suitable for long-distance overseas shipping and field deployment |
|
Throughput flexibility |
AIMDX 1800 for immediate single testing; AIMDX 8800 for 8 samples in parallel |
Covers everything from a single clinic to regional screening programmes |
|
Connectivity |
Result export and LIS/HL7 integration |
Connects to existing laboratory and hospital information systems |
5. Scenario Fit Matrix
The table below maps each scenario to the recommended instrument configuration and assay panel. Scenario descriptions are covered in the companion document, Molecular POCT Application Scenarios.
|
Scenario |
Recommended configuration |
Corresponding panel |
|
Emergency department / primary care clinics |
AIMDX 1800 |
Respiratory 8-plex (COVID-19, FluA, FluB, RSV, Adenovirus, Rhino, Mycoplasma, PIV) |
|
Infection control & pre-surgical screening |
AIMDX 1800 / 8800 |
MRSA, GBS, HBV DNA, HCV RNA, HBV/HCV, HBV/HCV/HIV |
|
Women's health & STD screening |
AIMDX 1800 / 8800 |
HPV 16/18 genotyping plus 14 pooled types; STD 3-plex (CT/UU/NG) |
|
Tuberculosis control |
AIMDX 1800 |
MTB nucleic acid detection kit (listed in the EU Declaration of Conformity signed 2025-05-20) |
|
Arboviral / tropical disease |
AIMDX 1800 |
Arbovirus 8-plex (Dengue 1–4, Yellow Fever, West Nile, Zika, Chikungunya) |
|
Feline / canine practice |
AIMDX 1800 |
Feline: FHV, FCV, Mycoplasma, Chlamydia, Bordetella, FPV, FCoV, Giardia, Cryptosporidium, FIP. Canine: CDV, CPV, CCoV, CRV, adenovirus I/II, parainfluenza, Giardia |
|
Equine / exotic animals |
AIMDX 1800 |
Streptococcus equi, equid herpesvirus 1/4, equine influenza A, Tritrichomonas foetus |
|
Swine / poultry farming and quarantine |
AIMDX 1800 / 8800 |
Swine: ASFV, FMDV, CSF, PRRSV-1/2. Poultry: Mycoplasma gallisepticum, Avibacterium paragallinarum, IBV, H9N2, H5N1/Newcastle disease |
|
Aquaculture |
AIMDX 1800 |
Tilapia, shrimp and koi carp kits |
|
Border posts / emergency response |
AIMDX 1800 (portable deployment) |
Multi-target panel selected for the target pathogens |
6. Deployment, Implementation & Support
Free pre-sales consultation
Installation and environment: benchtop deployment requiring only mains power and a level bench; vehicle, farm and border configurations can be arranged as mobile setups [exact environmental requirements are defined in the IFU].
Product Customisation Services
Operator training: operators can work independently after training; no PCR laboratory certification is required [regulatory requirements vary by market and the local competent authority prevails].
Free Sample Service
Quality system: every cartridge batch is quality-controlled before release; positive and negative controls plus internal QC procedures are recommended.
Multi-channel logistics services
Reagent storage and shipping: freeze-dried cartridges are stored and shipped at the labelled temperature, with overseas cold-chain dispatch supported.
After-sales technical support
After-sales service: remote support, on-site service and backup instrument options [service levels and response times to be provided by the commercial team].
After-sales warranty service
Distributor support: demo units, application training, territory protection, MOQ policy and joint marketing (see the Distributor Recruitment page).
7. FAQ (Solution)
Q1: What is the Aimbio molecular POCT solution?
Q2: How fast does it deliver results?
Q3: Do I need a PCR laboratory?
Q4: How many targets and samples?
Q5: What is the assay sensitivity?
Q6: Which sample types are supported?
Q7: Can results be integrated with our LIS?
Q8: What support do distributors receive?
8. Solving practical challenges in molecular testing
Simplify complex testing workflows
Molecular testing often involves separate steps for sample preparation, nucleic acid extraction and PCR analysis. Aimbio integrates extraction, purification, reagent reconstitution, amplification and detection in a single cartridge, reducing manual steps in the testing workflow.
Reduce sample handling with a closed cartridge
Transferring samples and reagents between separate processing steps adds handling requirements. The AIM Cartridge keeps the workflow inside a closed, single-use cartridge after sample loading, reducing the need for open transfers during processing.
Match testing capacity to your workload
Testing needs vary from individual samples to batch screening. The AIMDX 1800 and AIMDX 8800 offer different processing configurations, including parallel sample testing on the AIMDX 8800, so users can select a platform that fits their testing volume.
Connect results with your existing systems
Manually transferring results between instruments and laboratory systems creates additional work. Aimbio supports result export and LIS/HL7 connectivity to help laboratories incorporate testing results into their existing information workflows.