Hcv By Quantitative Naat

Hcv By Quantitative Naat
Details:
Hepatitis C Virus Quantitative Detection Kit
The Hepatitis C Virus Quantitative Detection Kit is intended for the quantitative in vitro detection of Hepatitis C Virus (HCV). It is intended for scientific research use by professionals only.
Send Inquiry
Download
Description
Technical Parameters

Hangzhou Aimbio Technology Co., Ltd. is one of the leading manufacturers and suppliers of hcv by quantitative naat in China. We are committed to providing high quality customized products with competitive price. If you're going to buy bulk advanced test kits made in China, welcome to get quotation from our factory.

 

 
Product Details

Item

Description

Reference code

HA-014

Product title

Hepatitis C Virus Quantitative Detection Kit

Application

Quantitative detection; scientific research use

Targets

HCV RNA

Specimen

Serum or plasma

Instrument

AIMDX1800 analyzer

Pack

1 test/bag; 4 tests/box

Storage

2°C to 8°C; 12 months

  • Source: HA-014 Instructions for Use

RNA Quantification

 

The kit uses real-time reverse transcription fluorescent PCR technology. According to the standard curve, the instrument will automatically calculate the HCV RNA content in the sample.

Sample Preservation

 

Samples can be tested immediately or stored at 2-8°C for up to 72 hours. For longer storage, freeze samples at -20°C for up to 6 months or below -70°C for extended periods. Avoid repeated freeze-thaw cycles. Use dry ice or ice packs in sealed foam boxes for transportation.

 
 

Reagents and controls

The lyophilized reagent includes specific primers, probes, reverse transcriptase, DNA polymerase, dNTPs, buffers, and lyophilization protectants. This product does not include live samples as positive controls. Instead, it provides artificially synthesized specific fragment standards as positive controls.

 
 
 

Analytical performance

The analytical performance of this kit was evaluated against endogenous and exogenous interfering substances. These substances were diluted to effective concentrations, and verification demonstrated that the following had no significant impact on the test results: 10 mmol/L triglycerides, 120 g/L hemoglobin, 20 IU/mL sodium heparin, 2 mg/mL EDTA, and 75 g/L human albumin. Clinical judgment should incorporate other diagnostic information, and retesting may be necessary. Insufficient sample volume may lead to false negatives.

 
 
 

Storage conditions

The Hepatitis C Virus Quantitative Detection Kit should be stored at 2°C to 8°C in a dark, sealed condition, with a shelf life of 12 months.

 

 

FAQ

 

 

 
01
 

Q: Suitable sample types?

A: Serum or plasma.

 
02
 

Q: Who performs testing?

A: Laboratory personnel must receive professional training, and all consumables should be sterilized and used only once.

 
02
 

Q: When should cartridges be used?

A: Once opened, the detection cartridges should be used within 24 hours.

 
03
 

Q: What is the detection limit?

A: The lowest detection limit is 100 copies/mL.

01mainimage

 

 